Holiday Inn, Wembley Stadium Park

November 13 2019by Maximum Climate Control

Maximum Air Con - Wembley

The Holiday Inn, Wembley Stadium Park, London

This was a 330 Bedroom Hotel re-fit.

The project involved removing the old LPHW heating system and replace the heating with a heat recovery system combined within the building. The Hotel was refurbished with the only the closing of individual floors, while the hotel remained fully operational apart from the floors being worked on. This project took just over a year to complete and was installed using 30 x Daikin VRV heat recovery outdoor systems, connected to 330 x ducted air conditioning indoor fan coils.

local-air-conditioning-services

All the bedroom units where individually controlled within each room. We also fitted an I Touch manager installed at reception to control any one room at any time if the guest required assistance from there room.

We also designed and installed a trickle vent fresh air system to all 330 bedrooms, to allow natural ventilation of the bedrooms and to be silent even at the 10th floor with strong winter winds, this proved very challenging but the customer is very happy with the end result.

 

We also refurbished the bathroom extract systems at the same time, and commissioned them.

maximum-air-con-wembley

The whole system was fully commissioned and handed over to the customer on time and within budget.

We also maintain the systems for the client to allow them peace of mind and there 5-year warranty.

Established in 1997, Maximum specialise in the design, installation, service and maintenance of HVAC systems (heating, ventilation and air conditioning), ranging from small heating, cooling and ventilation systems to VRV / VRF systems & heat recovery systems. If you’re interested in our services, be sure to get in touch with our specialists today!

Share this article

Carry on reading

August 27 2026By Maximum Climate Control

What Size Mini Split AC Installation Does Your Room Actually Need?

When a mini split AC installation is the wrong capacity for the room, the results show up quickly. Too small, and the unit runs flat out without reaching the temperature you have set. Too large, and it cools the air […]

mini split ac installation

July 28 2026By Maximum Climate Control

Why Is Commercial AC Unit Installation Key for UK Restaurants?

However good the food is, a restaurant that feels warm and stuffy leaves the wrong impression. A busy kitchen produces a great deal of heat, fumes and vapour, and dealing with that takes two systems working together. Kitchen extraction and […]

commercial AC unit installation