Smith & Wollensky, John Adam Street

June 23 2020by Maximum Climate Control

Smith-Wollensky-Restaurant-Adelphi-Building

Smith & Wollensky – US Steakhouse

Behind-the-scenes refrigeration and ducted air conditioning systems from Daikin UK are helping high-end US steakhouse chain Smith & Wollensky deliver its unique blend of flavour and service in central London – its first site outside America.

Smith & Wollensky – the names were randomly picked from a phone book – has enjoyed consistent success over eight US sites since its founding in 1977. It opened its 360-seat, 15,000 square foot London restaurant in 2015, taking a strategic street corner of the iconic Adelphi office building on John Adam Street.

Restaurant Air Conditioning

Nathan Evans, European Director for Smith & Wollensky, says alongside an excellent menu and top-class service, air conditioning is an important contributor to the overall customer experience. “People don’t relax if they aren’t comfortable. Air quality and temperature are the keys to comfort.”

Comfortable temperatures are assured in the restaurant’s ground and lower-ground floors with a 56hp bank of five Daikin VRV III heat recovery condensing units, mounted in a well-ventilated sub-basement, two floors further down. Their output serves 19 FXSQ-type ducted fan coil units concealed in ceiling voids in public areas and four FXAQ wall-mounted fan coil units in service areas.

Also in the sub-basement plant area are two ZEAS condensing units, totalling 15hp, and a ZEAS booster unit, which supply the restaurant’s refrigeration requirements – including a steady 5oC in the all important meat ageing room.

Smith-Wollensky-Restaurant-Adelphi-Building

Heat Recovery & Cooling For Restuarants

Cooking at the cold end of the kitchen – where the non-steak menu choices are prepared – is entirely on induction hobs to minimise energy costs and heat wastage.

Energy efficiency is a prime ingredient of all the Daikin solutions installed at Smith & Wollensky. The ZEAS units, for example, have a better refrigeration capacity to power consumption ratio than industry standard systems – and COPs of up to 3.0. Their inverter control boosts efficiency and minimises CO2 emissions.

ZEAS units provide an adaptable and controllable solution for all kinds of environment with fluctuating loads. Their small footprint and low sound levels offer installation flexibility – allowing larger capacities in small spaces.

Daikin VRV IV heat recovery systems are available from 8hp to 54hp with nominal heating/cooling outputs from 22.4kW to 151.2kW. As three-pipe systems they can simultaneously deliver heating and cooling to different areas – increasing the overall efficiency of the VRV system by allowing waste heat to be used to warm cool areas or for domestic hot water production.

FXSQ concealed ceiling units are available in 11 capacities, from (nominal) cooling 1.7kW and heating 1.9kW to 16kW cooling and 18kW heating.

Smith-Wollensky-Restaurant-Adelphi-Building

Smith & Wollensky Ventilation Systems

The restaurant is ventilated by seven VAM heat reclaim ventilation units with capacity to bring up to 13,000m3 of tempered fresh air into the premises every hour. The VAM units’ heat reclaim facility helps to minimise indoor-outdoor temperature differentials, avoiding excessive loads on the VRV units.

CO2 sensors continuously monitor the air flow to ensure that the VAM units operate as economically as possible, delivering only the volumes of fresh air required to maintain indoor air quality.

A separate inverter controlled condensing unit is connected to a DX coil in the air handling unit that ventilates the kitchen, which is also on the lower ground floor.

The kitchen has markedly different ‘hot’ and ‘cold’ ends. The hot end is where steaks are grilled to perfection. They are cooked on a vast range capable of holding 150 at a time – a necessary facility when steak is on the menu for large private dining occasions.

Installed systems

Established in 1997, Maximum specialise in the design, installation, service and maintenance of HVAC systems (heating, ventilation and air conditioning), ranging from small heating, cooling and ventilation systems to VRV / VRF systems & heat recovery systems. If you’re interested in our services, be sure to get in touch with our specialists today!

Share this article

Carry on reading

December 26 2024By Maximum Climate Control

Commercial Aircon Service in the UK – Things to Consider When Hiring Experts

It is now commonplace for UK commercial properties to have air conditioners with the aircon market projected to grow to $315BN. Commercial ACs are more common than domestic ones. Offices, restaurants, hotels, malls, server rooms and even beauty salons have […]

Commercial Aircon Service

December 11 2024By Maximum Climate Control

How Can Expert Commercial AC Unit Installation Lower Your Business Energy Bills?

Have you ever stopped to think about how your air conditioning system affects your business’s energy bills? You might not realise it, but an improperly installed AC unit can waste a significant amount of energy, driving up costs significantly. With […]

Commercial AC Unit Installation